Latest revision as of 13:18, 29 December 2006
17569/P1161 - Manifold Temp Sensor (G72): Open or Short to +
Possible Symptoms
- Probably no symptoms
Possible Causes
- Failure in wiring and/or connections
- Manifold Temp Sensor (G72) is defective
Possible Solutions
- Check wiring and connections
- Replace Manifold Temp Sensor (G72)