== 01274 - Air Flow Flap Positioning Motor (V71) ==
 
== 01274 - Air Flow Flap Positioning Motor (V71) ==
 +
 +
=== 01274 - Air Flow Flap Positioning Motor (V71): Faulty ===
  
 
==== Possible Causes ====
 
==== Possible Causes ====
  
* Short/Open Circuit<br>
+
* Wiring/Connectors from/to Air Flow Flap Positioning Motor (V71) falty
* Air Flow Flap Motor (V71) malfunctioning<br>
+
* Positioning Air Flow Flap Positioning Motor (V71) blocked
* Air Flow Flap Motor (V71) blocked<br>
+
* Positioning Air Flow Flap Positioning Motor (V71) faulty
  
 
==== Possible Solutions ====
 
==== Possible Solutions ====
  
* Check Air Flow Flap Motor (V71) (see Measuring Blocks)<br>
+
* Check Air Flow Flap Positioning Motor (V71)
* Perform Output Test<br>
+
** See Measuring Value Blocks (MVB)
* Perform Basic Setting<br>
+
** Perform Output Test
* Check/Repair Wiring and Connectors<br>
+
** Perform Basic Setting
 
+
* Check/Repair Wiring and Connectors
  
--[[User:Sebastian|Sebastian]] 21:06, 18 December 2005 (Eastern Standard Time)
 
 
[[Category:Fault Codes]]
 
[[Category:Fault Codes]]

Revision as of 13:56, 14 March 2007

01274 - Air Flow Flap Positioning Motor (V71)

01274 - Air Flow Flap Positioning Motor (V71): Faulty

Possible Causes

  • Wiring/Connectors from/to Air Flow Flap Positioning Motor (V71) falty
  • Positioning Air Flow Flap Positioning Motor (V71) blocked
  • Positioning Air Flow Flap Positioning Motor (V71) faulty

Possible Solutions

  • Check Air Flow Flap Positioning Motor (V71)
    • See Measuring Value Blocks (MVB)
    • Perform Output Test
    • Perform Basic Setting
  • Check/Repair Wiring and Connectors