01274: Difference between revisions
From Ross-Tech Wiki
Table Of Contents
RtWiKiSyS0p (talk | contribs) No edit summary |
RtWiKiSyS0p (talk | contribs) mNo edit summary |
||
| Line 1: | Line 1: | ||
__FORCETOC__ | __FORCETOC__ | ||
== 01274 - Air Flow Flap Positioning Motor (V71) == | == 01274 - Air Flow Flap Positioning Motor (V71) == | ||
=== 01274 - Air Flow Flap Positioning Motor (V71): Faulty === | |||
==== Possible Causes ==== | ==== Possible Causes ==== | ||
* | * Wiring/Connectors from/to Air Flow Flap Positioning Motor (V71) falty | ||
* Air Flow Flap Motor (V71) | * Positioning Air Flow Flap Positioning Motor (V71) blocked | ||
* Air Flow Flap Motor (V71) | * Positioning Air Flow Flap Positioning Motor (V71) faulty | ||
==== Possible Solutions ==== | ==== Possible Solutions ==== | ||
* Check Air Flow Flap Motor (V71) | * Check Air Flow Flap Positioning Motor (V71) | ||
* Perform Output Test | ** See Measuring Value Blocks (MVB) | ||
* Perform Basic Setting | ** Perform Output Test | ||
* Check/Repair Wiring and Connectors | ** Perform Basic Setting | ||
* Check/Repair Wiring and Connectors | |||
[[Category:Fault Codes]] | [[Category:Fault Codes]] | ||
Revision as of 18:56, 14 March 2007
01274 - Air Flow Flap Positioning Motor (V71)
01274 - Air Flow Flap Positioning Motor (V71): Faulty
Possible Causes
- Wiring/Connectors from/to Air Flow Flap Positioning Motor (V71) falty
- Positioning Air Flow Flap Positioning Motor (V71) blocked
- Positioning Air Flow Flap Positioning Motor (V71) faulty
Possible Solutions
- Check Air Flow Flap Positioning Motor (V71)
- See Measuring Value Blocks (MVB)
- Perform Output Test
- Perform Basic Setting
- Check/Repair Wiring and Connectors