== 00266 - Solenoid valve 5 (N92): open circuit / short to ground ==
+
== 00266 - Solenoid Valve 5 (N92) ==
 +
=== 00266 - Solenoid Valve 5 (N92): Open or Short to Ground ===
  
 
==== Possible Causes ====
 
==== Possible Causes ====
  
* Open circuit or short circuit in wiring
+
* Wiring/Connectors from/to Solenoid Valve 5 (N92) Open or Short to Ground
* (B1 break) Malfunctioning solenoid valve 5
+
* Solenoid Valve 5 (N92) faulty
  
 
==== Possible Solutions ====
 
==== Possible Solutions ====
  
* Check wiring, connections and solenoid
+
* Check/Repair Wiring/Connectors from/to Solenoid Valve 5 (N92)
* Replace N92
+
* Check/Replace Solenoid Valve 5 (N92)
 +
** See Measuring Value Blocks (MVB)
 +
** Perform Output Test
  
 
[[Category:Fault Codes]]
 
[[Category:Fault Codes]]

Revision as of 04:30, 22 March 2007

00266 - Solenoid Valve 5 (N92)

00266 - Solenoid Valve 5 (N92): Open or Short to Ground

Possible Causes

  • Wiring/Connectors from/to Solenoid Valve 5 (N92) Open or Short to Ground
  • Solenoid Valve 5 (N92) faulty

Possible Solutions

  • Check/Repair Wiring/Connectors from/to Solenoid Valve 5 (N92)
  • Check/Replace Solenoid Valve 5 (N92)
    • See Measuring Value Blocks (MVB)