00532 - Supply Voltage B+
00532 - Supply Voltage B+: Signal too Low
Possible Causes
- Wiring/Connectors from/to Control Module faulty
- Power Supply (Battery/Generator) faulty
Possible Solutions
- Check/Repair Wiring/Connectors from/to Control Module
- Check Power Supply (Battery/Generator)
Special Notes
- When found in an individual control module, it's most likely a local source (e.g. wiring/connectors).
- When found in multiple control modules at the same time, it's most likely a common source (e.g. ground spot, battery, generator).