Difference between revisions of "00816"

From Ross-Tech Wiki
 
m
Line 2: Line 2:
 
== 00816 - Power Steering Sensor (G250) ==
 
== 00816 - Power Steering Sensor (G250) ==
  
=== 00816 - Power Steering Sensor (G250): Open or Short to B+ ===
+
=== 00816 - Power Steering Sensor (G250): Short to Ground ===
 +
=== 00816 - Power Steering Sensor (G250): Open or Short to Plus ===
 +
=== 00816 - Power Steering Sensor (G250): Faulty ===
  
 
==== Possible Symptoms ====
 
==== Possible Symptoms ====

Revision as of 11:50, 22 April 2007

00816 - Power Steering Sensor (G250)

00816 - Power Steering Sensor (G250): Short to Ground

00816 - Power Steering Sensor (G250): Open or Short to Plus

00816 - Power Steering Sensor (G250): Faulty

Possible Symptoms

  • Steering stiff
  • Power Steering in Emergency Mode
  • Malfunction Indicator Light (MIL) active

Possible Causes

  • Wiring/Connectors from/to Power Steering Sensor (G250) faulty
  • Power Steering Sensor (G250) faulty

Possible Solutions

  • Check Measuring Value Blocks (MVB)
  • Check Wiring/Connectors from/to Power Steering Sensor (G250)
  • Check Power Steering Sensor (G250)