Difference between revisions of "01423"
From Ross-Tech Wiki
RtWiKiSyS0p (talk | contribs) m |
RtWiKiSyS0p (talk | contribs) |
||
Line 1: | Line 1: | ||
__FORCETOC__ | __FORCETOC__ | ||
== 01423 - Lateral Acceleration Sensor (G200) == | == 01423 - Lateral Acceleration Sensor (G200) == | ||
+ | |||
+ | === 01423 - Lateral Acceleration Sensor (G200): No or Incorrect Basic Setting / Adaptation === | ||
+ | |||
+ | ==== Possible Symptoms ==== | ||
+ | |||
+ | * Malfunction Indicator Light (MIL) active | ||
+ | |||
+ | ==== Possible Causes ==== | ||
+ | |||
+ | * Basic Setting not performed | ||
+ | |||
+ | ==== Possible Solutions ==== | ||
+ | |||
+ | * Perform Basic Setting | ||
+ | |||
=== 01423 - Lateral Acceleration Sensor (G200): Electric Circuit Failure === | === 01423 - Lateral Acceleration Sensor (G200): Electric Circuit Failure === |
Revision as of 12:48, 10 November 2007
01423 - Lateral Acceleration Sensor (G200)
01423 - Lateral Acceleration Sensor (G200): No or Incorrect Basic Setting / Adaptation
Possible Symptoms
- Malfunction Indicator Light (MIL) active
Possible Causes
- Basic Setting not performed
Possible Solutions
- Perform Basic Setting
01423 - Lateral Acceleration Sensor (G200): Electric Circuit Failure
Possible Symptoms
- Malfunction Indicator Light (MIL) active
Possible Causes
- Wiring/Connections from/to Lateral Acceleration Sensor (G200) faulty
- Supply Voltage insufficient
- Lateral Acceleration Sensor (G200) faulty
Possible Solutions
- Check Wiring/Connections from/to Lateral Acceleration Sensor (G200)
- Check Supply Voltage
- Check Lateral Acceleration Sensor (G200) faulty
- Perform Lateral Acceleration Sensor (G200) Basic Setting