RtWiKiSyS0p (talk | contribs) (New page: __FORCETOC__ == Coding == * '''000xx?0''': ''Glass Type'' ** 2 = Standard Glass (Clear Glass) ** 3 = Thermal Protection Glass (Insulated/Acoustic Glass) * '''000xxx0''': ''Roof'' ** 0 = S...) |
RtWiKiSyS0p (talk | contribs) m |
||
Line 5: | Line 5: | ||
** 2 = Standard Glass (Clear Glass) | ** 2 = Standard Glass (Clear Glass) | ||
** 3 = Thermal Protection Glass (Insulated/Acoustic Glass) | ** 3 = Thermal Protection Glass (Insulated/Acoustic Glass) | ||
− | * ''' | + | * '''000x?x0''': ''Roof'' |
** 0 = Solar Roof not installed | ** 0 = Solar Roof not installed | ||
** 2 = Solar Roof installed | ** 2 = Solar Roof installed | ||
− | * ''' | + | * '''000?xx0''': ''Refrigerant Loss Recognition'' |
** 0 = Refrigerant Temperature Sensor installed ''(Recognition activated)'' | ** 0 = Refrigerant Temperature Sensor installed ''(Recognition activated)'' | ||
** 1 = Refrigerant Temperature Sensor not installed ''(Recognition deactivated)'' | ** 1 = Refrigerant Temperature Sensor not installed ''(Recognition deactivated)'' |
Revision as of 10:41, 21 November 2007
Coding
- 000xx?0: Glass Type
- 2 = Standard Glass (Clear Glass)
- 3 = Thermal Protection Glass (Insulated/Acoustic Glass)
- 000x?x0: Roof
- 0 = Solar Roof not installed
- 2 = Solar Roof installed
- 000?xx0: Refrigerant Loss Recognition
- 0 = Refrigerant Temperature Sensor installed (Recognition activated)
- 1 = Refrigerant Temperature Sensor not installed (Recognition deactivated)
Basic Setting
Normal (Potentiometer & Flap Adaptation)
Prerequisites:
[Select]
[08 - Heating/Air Conditioning]
[Basic Settings - 04]
Group 001
[Go!]
Activate the Basic Setting.
[ON/OFF/Next]
The basic setting takes approximately 25 seconds.
[Done, Go Back]
[Close Controller, Go Back - 06]
Service Position
Notes:
- Has to be performed before ANY Actuators/Motors are being removed.
- While in Service Position the Display reads SF (German for "Servicefall").
- Make sure to have the Ignition OFF while working on the Actuators/Motors.
- Once all work has been done, switch ON the Ignition and perform the normal Basic Setting (Potentiometer & Flap Adaptation).
[Select]
[08 - Heating/Air Conditioning]
[Basic Settings - 04]
Group 002
[Go!]
Activate the Basic Setting.
[ON/OFF/Next]
The Display should read SFnow.
[Done, Go Back]
[Close Controller, Go Back - 06]