Difference between revisions of "VW Touareg (7L) Heating/Air Conditioning"

From Ross-Tech Wiki
(New page: __FORCETOC__ == Coding == * '''000xx?0''': ''Glass Type'' ** 2 = Standard Glass (Clear Glass) ** 3 = Thermal Protection Glass (Insulated/Acoustic Glass) * '''000xxx0''': ''Roof'' ** 0 = S...)
 
m
Line 5: Line 5:
 
** 2 = Standard Glass (Clear Glass)
 
** 2 = Standard Glass (Clear Glass)
 
** 3 = Thermal Protection Glass (Insulated/Acoustic Glass)
 
** 3 = Thermal Protection Glass (Insulated/Acoustic Glass)
* '''000xxx0''': ''Roof''
+
* '''000x?x0''': ''Roof''
 
** 0 = Solar Roof not installed
 
** 0 = Solar Roof not installed
 
** 2 = Solar Roof installed
 
** 2 = Solar Roof installed
* '''000xxx0''': ''Refrigerant Loss Recognition''
+
* '''000?xx0''': ''Refrigerant Loss Recognition''
 
** 0 = Refrigerant Temperature Sensor installed ''(Recognition activated)''
 
** 0 = Refrigerant Temperature Sensor installed ''(Recognition activated)''
 
** 1 = Refrigerant Temperature Sensor not installed ''(Recognition deactivated)''
 
** 1 = Refrigerant Temperature Sensor not installed ''(Recognition deactivated)''

Revision as of 10:41, 21 November 2007

Coding

  • 000xx?0: Glass Type
    • 2 = Standard Glass (Clear Glass)
    • 3 = Thermal Protection Glass (Insulated/Acoustic Glass)
  • 000x?x0: Roof
    • 0 = Solar Roof not installed
    • 2 = Solar Roof installed
  • 000?xx0: Refrigerant Loss Recognition
    • 0 = Refrigerant Temperature Sensor installed (Recognition activated)
    • 1 = Refrigerant Temperature Sensor not installed (Recognition deactivated)


Basic Setting

Normal (Potentiometer & Flap Adaptation)

Prerequisites:

[Select]
[08 - Heating/Air Conditioning]
[Basic Settings - 04]
Group 001
[Go!]
Activate the Basic Setting.
[ON/OFF/Next]
The basic setting takes approximately 25 seconds.
[Done, Go Back]
[Close Controller, Go Back - 06]


Service Position

Notes:

  • Has to be performed before ANY Actuators/Motors are being removed.
  • While in Service Position the Display reads SF (German for "Servicefall").
  • Make sure to have the Ignition OFF while working on the Actuators/Motors.
  • Once all work has been done, switch ON the Ignition and perform the normal Basic Setting (Potentiometer & Flap Adaptation).

[Select]
[08 - Heating/Air Conditioning]
[Basic Settings - 04]
Group 002
[Go!]
Activate the Basic Setting.
[ON/OFF/Next]
The Display should read SFnow.
[Done, Go Back]
[Close Controller, Go Back - 06]