Difference between revisions of "17608/P1200/004608"
From Ross-Tech Wiki
RtWiKiSyS0p (talk | contribs) m |
RtWiKiSyS0p (talk | contribs) |
||
Line 4: | Line 4: | ||
==== Possible Symptoms ==== | ==== Possible Symptoms ==== | ||
+ | * Malfunction Indicator Light (MIL) ON | ||
* Power Loss | * Power Loss | ||
+ | |||
+ | ==== Possible Causes ==== | ||
+ | |||
+ | * Boost Pressure Control Valve (N249) faulty | ||
+ | * Diverter Valve faulty | ||
==== Possible Solutions ==== | ==== Possible Solutions ==== | ||
− | * Check Boost Pressure Control Valve (N249) | + | * Check / Replace Boost Pressure Control Valve (N249) |
+ | * Check / Replace Diverter Valve | ||
[[Category:Fault Codes]] | [[Category:Fault Codes]] |
Latest revision as of 12:02, 15 June 2010
17608/P1200/004608 - Boost Pressure Control Valve (N249): Mechanical Malfunction
Possible Symptoms
- Malfunction Indicator Light (MIL) ON
- Power Loss
Possible Causes
- Boost Pressure Control Valve (N249) faulty
- Diverter Valve faulty
Possible Solutions
- Check / Replace Boost Pressure Control Valve (N249)
- Check / Replace Diverter Valve