Difference between revisions of "01814"

From Ross-Tech Wiki
(Created page with '== 01814 - Supply Voltage for Door Controller; Rear Right (J389) == === 01814 - Supply Voltage for Door Controller; Rear Right (J389): Lower Limit Exceeded === ==== Possible Sy…')
 
m
 
Line 16: Line 16:
  
 
* Check Fuse(s)
 
* Check Fuse(s)
** Check Door Controller Rear Right (J389) Measuring Value Block (MVB)
+
** Check Door Controller Rear Right (J389) Measuring Value Blocks (MVB)
 
* Check Wiring and/or Connector(s) from/to Door Controller Rear Right (J389)
 
* Check Wiring and/or Connector(s) from/to Door Controller Rear Right (J389)
  
 
__FORCETOC__
 
__FORCETOC__
 
[[Category:Fault Codes]]
 
[[Category:Fault Codes]]

Latest revision as of 23:06, 4 December 2010

01814 - Supply Voltage for Door Controller; Rear Right (J389)

01814 - Supply Voltage for Door Controller; Rear Right (J389): Lower Limit Exceeded

Possible Symptoms

  • Door Controller Functionality limited
  • Window Regulator not working

Possible Causes

  • Fuse(s) faulty
  • Wiring and/or Connector(s) from/to Door Controller Rear Right (J389) faulty

Possible Solutions

  • Check Fuse(s)
    • Check Door Controller Rear Right (J389) Measuring Value Blocks (MVB)
  • Check Wiring and/or Connector(s) from/to Door Controller Rear Right (J389)