Difference between revisions of "01813"

From Ross-Tech Wiki
(Created page with '== 01813 - Supply Voltage for Door Controller; Rear Left (J388) == === 01813 - Supply Voltage for Door Controller; Rear Left (J388): Lower Limit Exceeded === ==== Possible Symp…')
 
m
 
Line 5: Line 5:
 
==== Possible Symptoms ====
 
==== Possible Symptoms ====
  
* Door Controller Functionality
+
* Door Controller Functionality limited
 
* Window Regulator not working
 
* Window Regulator not working
  

Latest revision as of 23:06, 4 December 2010

01813 - Supply Voltage for Door Controller; Rear Left (J388)

01813 - Supply Voltage for Door Controller; Rear Left (J388): Lower Limit Exceeded

Possible Symptoms

  • Door Controller Functionality limited
  • Window Regulator not working

Possible Causes

  • Fuse(s) faulty
  • Wiring and/or Connector(s) from/to Door Controller Rear Left (J388) faulty

Possible Solutions

  • Check Fuse(s)
    • Check Door Controller Rear Left (J388) Measuring Value Blocks (MVB)
  • Check Wiring and/or Connector(s) from/to Door Controller Rear Left (J388)