Difference between revisions of "00655"
From Ross-Tech Wiki
RtWiKiSyS0p (talk | contribs) (New page: __FORCETOC__ == 00655 - Seat Belt Tensioner Igniter Passenger Side (N154) == === 00655 - Seat Belt Tensioner Igniter Passenger Side (N154): Resistance too High === ==== Possible Symptoms...) |
|||
Line 3: | Line 3: | ||
=== 00655 - Seat Belt Tensioner Igniter Passenger Side (N154): Resistance too High === | === 00655 - Seat Belt Tensioner Igniter Passenger Side (N154): Resistance too High === | ||
+ | === 00655 - Seat Belt Tensioner Igniter Passenger Side (N154): Short to positive === | ||
+ | === 00655 - Seat Belt Tensioner Igniter Passenger Side (N154): Short to ground === | ||
==== Possible Symptoms ==== | ==== Possible Symptoms ==== | ||
Line 18: | Line 20: | ||
** Check Measuring Value Blocks (MVB) | ** Check Measuring Value Blocks (MVB) | ||
* Check Seat Belt Tensioner Igniter Passenger Side (N154) | * Check Seat Belt Tensioner Igniter Passenger Side (N154) | ||
+ | |||
+ | ==== Special Notes ==== | ||
+ | |||
+ | * When "Short to positive" or "Short to ground" is found, '''DO NOT CLEAR THE DTC'''. This can cause the tensioner to deploy. See repair manual for more information. | ||
+ | |||
[[Category:Fault Codes]] | [[Category:Fault Codes]] |
Latest revision as of 14:17, 14 December 2010
00655 - Seat Belt Tensioner Igniter Passenger Side (N154)
00655 - Seat Belt Tensioner Igniter Passenger Side (N154): Resistance too High
00655 - Seat Belt Tensioner Igniter Passenger Side (N154): Short to positive
00655 - Seat Belt Tensioner Igniter Passenger Side (N154): Short to ground
Possible Symptoms
- Malfuncton Indicator Light (MIL) active
Possible Causes
- Wiring/Connectors from/to Seat Belt Tensioner Igniter Passenger Side (N154) faulty
- Seat Belt Tensioner Igniter Passenger Side (N154) faulty
Possible Solutions
- Check Wiring/Connectors from/to Seat Belt Tensioner Igniter Passenger Side (N154)
- Check Measuring Value Blocks (MVB)
- Check Seat Belt Tensioner Igniter Passenger Side (N154)
Special Notes
- When "Short to positive" or "Short to ground" is found, DO NOT CLEAR THE DTC. This can cause the tensioner to deploy. See repair manual for more information.