Difference between revisions of "18565/P2133"
From Ross-Tech Wiki
(Created page with '__FORCETOC__ == 18565/P2133 - Throttle Position Sensor Bank 2: Signal too High == ==== Possible Symptoms ==== * MIL on * Reduced Power Output ==== Possible Causes ==== * Fau…') |
|||
Line 23: | Line 23: | ||
* O2 sensor issues can also cause the following DTCs: | * O2 sensor issues can also cause the following DTCs: | ||
− | **16610 - Throttle Pedal Position Sensor (G79): Implausible Signal | + | **[[16610/P0226]] - Throttle Pedal Position Sensor (G79): Implausible Signal |
− | ** | + | **[[18560P2128]] - Accelerator Position Sensor 2 (G185): Signal too High |
* In some cases, O2 sensors will damage the ECM. Ross Tech suggest to replace O2 sensors ''before'' replacing an ECM for this type of issue. | * In some cases, O2 sensors will damage the ECM. Ross Tech suggest to replace O2 sensors ''before'' replacing an ECM for this type of issue. | ||
Revision as of 17:39, 16 February 2012
18565/P2133 - Throttle Position Sensor Bank 2: Signal too High
Possible Symptoms
- MIL on
- Reduced Power Output
Possible Causes
- Faulty Accelerator Pedal (very unlikely)
- Wiring Harness Issue
- Faulty ECM
- O2 Sensor(s)
Possible Solutions
- Inspect and test Wiring harness for Accelerator Pedal, see Repair Manual
- Visually inspect O2 sensors for damage
Special Notes
- O2 sensor issues can also cause the following DTCs:
- 16610/P0226 - Throttle Pedal Position Sensor (G79): Implausible Signal
- 18560P2128 - Accelerator Position Sensor 2 (G185): Signal too High
- In some cases, O2 sensors will damage the ECM. Ross Tech suggest to replace O2 sensors before replacing an ECM for this type of issue.