User:Peter: Difference between revisions
Table Of Contents
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
=== Electronic Damping Control J250 - Basic Settings === | === Electronic Damping Control J250 - Basic Settings === | ||
'''Prerequisites:'''<br> | |||
- Battery Voltage = 12.0 - 14.0'''<br> | |||
- No fault codes other than [01087-Basic Setting Not Performed]'''<br> | |||
- Vehicle is lifted off the ground, on a suitable vehicle lift'''<br> | |||
Line 5: | Line 11: | ||
'''[14 - Susp. Elect]'''<br> | '''[14 - Susp. Elect]'''<br> | ||
'''[Meas. Blocks - 08]'''<br> | '''[Meas. Blocks - 08]'''<br> | ||
Note the values | Note: The values stored in the Measuring Value Blocks below are the Minimum and Maximum sensor values.'''<br> | ||
Group-054 Field-1 = G78 | Group-054 Field-1 = G78 - Min value'''<br> | ||
Group-054 Field-2 = G78 | Group-054 Field-2 = G78 - Max value'''<br> | ||
<br> | <br> | ||
Look at:'''<br> | Group-055 Field-1 = G289 - Min value'''<br> | ||
Group-003 Field-1,2,3 | Group-055 Field-2 = G289 - Max value'''<br> | ||
- If the values are with in the range of the Min - Max'''<br> | <br> | ||
Basic settings can be performed, if not inspect suspension.'''<br> | '''Look at:'''<br> | ||
'''Group-003 - Field-1,2,3 - Actual Sensor values'<br> | |||
- If the values are with in the range of the Min - Max stored values from MVBs 054 and 055 then'''<br> | |||
Basic settings can be performed, if not inspect suspension or sensors.'''<br> | |||
<br> | <br> | ||
'''[Security Access - 16]'''<br> | '''[Security Access - 16]'''<br> | ||
Line 20: | Line 27: | ||
'''[Do it!]'''<br> | '''[Do it!]'''<br> | ||
'''[Basic Settings - 04]'''<br> | '''[Basic Settings - 04]'''<br> | ||
Group 001 | '''Group 001'''<br> | ||
'''[Go!]'''<br> | '''[Go!]'''<br> | ||
<br> | <br> |
Revision as of 15:11, 3 May 2013
Electronic Damping Control J250 - Basic Settings
Prerequisites:
- Battery Voltage = 12.0 - 14.0
- No fault codes other than [01087-Basic Setting Not Performed]
- Vehicle is lifted off the ground, on a suitable vehicle lift
[Select]
[14 - Susp. Elect]
[Meas. Blocks - 08]
Note: The values stored in the Measuring Value Blocks below are the Minimum and Maximum sensor values.
Group-054 Field-1 = G78 - Min value
Group-054 Field-2 = G78 - Max value
Group-055 Field-1 = G289 - Min value
Group-055 Field-2 = G289 - Max value
Look at:
Group-003 - Field-1,2,3 - Actual Sensor values'
- If the values are with in the range of the Min - Max stored values from MVBs 054 and 055 then
Basic settings can be performed, if not inspect suspension or sensors.
[Security Access - 16]
Enter 31564, to enable the basic setting.
[Do it!]
[Basic Settings - 04]
Group 001
[Go!]
The New values should be displayed.
- To check the learned values, check Measuring Value Group-008.
[Meas. Blocks - 08]
Enter [008] - Go!
The values displayed should be the learned values as displayed in the Basic Settings window.
No categories.