Latest revision as of 10:10, 22 May 2013
00268 - Solenoid Valve 6 (N93)
00268 - Solenoid Valve 6 (N93): Open or Short to Ground
Possible Causes
- Wiring/Connectors from/to Solenoid Valve 6 (N93) Open or Short to Ground
- Solenoid Valve 6 (N93) faulty
Possible Solutions
- Check/Repair Wiring/Connectors from/to Solenoid Valve 6 (N93)
- Check/Replace Solenoid Valve 6 (N93)
- See Measuring Value Blocks (MVB)
- Perform Output Test
Special Notes
- On some transmissions, the OE wiring diagrams do not have Solenoid Valve 6 (N93), it can be refereed to as the Pressure Control Valve 3 (N217).