Difference between revisions of "P189C/006300"

From Ross-Tech Wiki
m
Line 1: Line 1:
 
__FORCETOC__
 
__FORCETOC__
== 006300-Function Restriction due to Insufficient Pressure Build-Up ==
+
== P189C/006300 - Function Restriction due to Insufficient Pressure Build-Up ==
 
 
=== P189C/006300 - 006300-Function Restriction due to Insufficient Pressure Build-Up ===
 
 
 
 
==== Possible Symptoms ====
 
==== Possible Symptoms ====
  
Line 24: Line 21:
 
==== Special Notes ====
 
==== Special Notes ====
  
*  On the Seven speed AG7-DSG transmission check for battery power at Pin 9 of the 25-Pin connector.
+
*  On the 7-Speed Dual Clutch Transmission (DSG/0AM) transmission check for battery power at Pin 9 of the 25-Pin connector.
 
*  Once an effective repair has been completed, clear faults from Transmission Control Module and set Basic Settings.
 
*  Once an effective repair has been completed, clear faults from Transmission Control Module and set Basic Settings.
  
 
[[Category:Fault Codes]]
 
[[Category:Fault Codes]]

Revision as of 08:29, 2 December 2013

P189C/006300 - Function Restriction due to Insufficient Pressure Build-Up

Possible Symptoms

  • Unable to complete Basic Settings, fault will not clear from Transmission Control Module.

Possible Causes

  • Faulty wiring.
  • Faulty connections.
  • Faulty Fuse(s).
  • Faulty Mechatronic Unit, (V401-Hydraulic pump motor)


Possible Solutions

  • Check/repair/replace faulty wiring/connections.
  • Check/replace faulty fuse(s).
  • Replace faulty Mechatronic Unit.

Special Notes

  • On the 7-Speed Dual Clutch Transmission (DSG/0AM) transmission check for battery power at Pin 9 of the 25-Pin connector.
  • Once an effective repair has been completed, clear faults from Transmission Control Module and set Basic Settings.