19560/P3104/012548
From Ross-Tech Wiki
Revision as of 05:46, 10 August 2006 by RtWiKiSyS0p (talk | contribs)
19560/P3104/012548 - Valve for Intake Manifold Flap (N239): Short to Plus
Possible Symptoms
- Engines shakes at shutdown
Possible Causes
- Wiring Short to Plus
- Valve for Intake Manifold Flap (N239) faulty
Possible Solutions
- Check Wiring for Short to Plus
- Check Valve for Intake Manifold Flap (N239) > Output Test