01290
From Ross-Tech Wiki
Table Of Contents
-
1.
01290 - Reference Voltage Steering Assist
-
1.1.1
01290 - Reference Voltage Steering Assist: Short to Plus
- 1.1.1.2 Possible Symptoms
- 1.1.2.2 Possible Causes
- 1.1.3.2 Possible Solutions
-
1.2.1
01290 - Reference Voltage Steering Assist: Short to Ground
- 1.2.1.6 Possible Symptoms
- 1.2.2.6 Possible Causes
- 1.2.3.6 Possible Solutions
-
1.1.1
01290 - Reference Voltage Steering Assist: Short to Plus
01290 - Reference Voltage Steering Assist
01290 - Reference Voltage Steering Assist: Short to Plus
Possible Symptoms
- Malfunction Indicator Light (MIL) ON
- Power Steering not working
Possible Causes
- Wiring and/or Connector(s) from/to Sensor for Power Steering (G250) faulty
- Sensor for Power Steering (G250) faulty
Possible Solutions
- Check Wiring and/or Connector(s) from/to Sensor for Power Steering (G250)
- Check/Replace Sensor for Power Steering (G250)
- Check Measuring Value Block (MVB) 004.3
01290 - Reference Voltage Steering Assist: Short to Ground
Possible Symptoms
- Malfunction Indicator Light (MIL) ON
- Power Steering not working
Possible Causes
- Wiring and/or Connector(s) from/to Sensor for Power Steering (G250) faulty
- Sensor for Power Steering (G250) faulty
Possible Solutions
- Check Fuse(s)
- Check Wiring and/or Connector(s) from/to Sensor for Power Steering (G250)
- Check/Replace Sensor for Power Steering (G250)
- Check Measuring Value Block (MVB) 004.3