Basic Settings of the Active/Dynamic Steering
1B-Active Steering
Prerequisites:
- Battery Voltage = 12.0 - 14.0 V
- No fault codes other than 01087 - Basic Setting Not Performed
- Vehicle is lifted off the ground, on a suitable vehicle lift
- Perform G85-Steering Angle Sensor Basic Settings found on this Ross-Tech wiki page:
http://wiki.ross-tech.com/wiki/index.php/Audi_A5_%288T%29_Steering_Wheel_Electronics#Basic_Setting
- Continue only after successfully completing the G85 basic settings:
[Select]
[1B-Active Steering]
[Security Access - 16]
Enter 61378, to enable the basic setting.
[Do it!]
[Basic Settings - 04]
Group 101
[Go!]
[ON/OFF/Next]
- The results should be stored after a key cycle and fault code(s) should clear.
[Done, Go Back]
[Fault Codes - 02]
Check and clear fault codes.
[Close Controller, Go Back - 06]