Bentley Continental (3W) Automatic Roof
From Ross-Tech Wiki
Additional information can be found in the Official Factory Repair Information.
Adaptation
Prerequisites: End Stops
- Vehicle system voltage above 12.0v (Engine running)
- All doors and lids shut
- No faults in the 26-Automatic Roof controller
- Convertible Top in good condition, no damage
- Convertible Top Closed and locked
Channel 00: Delete End Stops
To reset the learned End Stops, save a new value of 0
- Then follow with the Relearn End Stops.
Channel 01: Relearn End Stops
To start the relearn the End Stops, save a new value of 1
- Open the Convertible Top to 'Relearn' the End Stops.
- Check for and clear any fault codes.
- Check for proper Convertible Top Operation