P00AF/000175

From Ross-Tech Wiki
Revision as of 07:44, 28 April 2022 by Sebastian1 (talk | contribs) (Sebastian1 moved page 000175 to P00AF/000175)

000175/P00AF - Actuator Module for Turbocharger 1: Stuck

Possible Symptoms

  • Malfunction Indicator Light (MIL) ON
  • Glow Plug light flashing
  • Reduced engine performance

Possible Causes

  • Defective N75
  • N75 connector plugged into the wrong 2 wire component. Check wiring diagram to confirm
  • Vacuum leak or low vacuum
  • VNT sticking or seized
  • G581 sensor

Possible Solutions

  • Verify N75 is working to design, use Output Testing
  • Verify the N75 connector plugged into N75 per the factory level wiring diagram rather than any other component that may not set a fault code such as N79 (Positive Crankcase Ventilation (PCV) heating element)
  • Verify vacuum lines are good, check engine vacuum at idle
  • Test VNT and G581, apply vacuum to VNT and watch MVB 120.4
    • Engine off, no vacuum 120.4 should read about 3.5V
    • Engine Off, apply 17 Inches of mercury, 120.4 should drop to about .7V
    • Engine at idle, 120.4 should read about .7V
    • If 120.4 voltage doesn't alter, VNT may be seized or G581 failed

Special Notes