02645 - Valves for Level Control System

02645 - Valves for Level Control System : Upper Limit

02645 - Valves for Level Control System : Lower Limit

02645 - Valves for Level Control System : Mechanical Fault

02645 - Valves for Level Control System : Open Circiut

02645 - Valves for Level Control System): Short-Circuit to Positive

02645 - Valves for Level Control System: Short-Circuit to Ground (GND)

Possible Symptoms

Possible Causes

  • Wiring issue between G291 sensor and J197 Control Module
  • Faulty G291 sensor
  • Faulty J197 Control Module
  • Air leak in system

Possible Solutions

  • Inspect and repair wiring harness
  • Inspect for leaks with soapy water

Additional Notes