01274
From Ross-Tech Wiki
Revision as of 21:06, 18 December 2005 by RtWiKiSyS0p (talk | contribs)
01274 - Air Flow Flap Positioning Motor (V71)
Possible Causes
- Short/Open Circuit
- Air Flow Flap Motor (V71) malfunctioning
- Air Flow Flap Motor (V71) blocked
Possible Solutions
- Check Air Flow Flap Motor (V71) (see Measuring Blocks)
- Perform Output Test
- Perform Basic Setting
- Check/Repair Wiring and Connectors
--Sebastian 21:06, 18 December 2005 (Eastern Standard Time)