3.0l V6 TDI (BKS/BMK/BUN)
          From Ross-Tech Wiki
          
          
      
      
      
      Table Of Contents
- 1. Coding
 - 2. Coding-II
 - 3. Adaptation
 - 4. Basic Setting
 - 5. Special Functions
 
Coding
Coding-II
- 10016 = Particle Filter Emergency Regeneration
 
Adaptation
Basic Setting
Special Functions
Particle Filter Emergency Regeneration
Prerequisites:
- Ignition ON
 - Engine ON (Idle)
 - Oil Temperature above 70 °C (see MVB 007.2)
 - Particle Filter Load below 68g (see MVB 104.3)
 - Engine Hood CLOSED
 - Parking Brake ENGAGED
 - Transmission in (P)ARK
 - Temperatures at the Exhaust System may rise up to 300 °C!!!
 - No Fault Codes Stored
 - Power Consumers ON (Light, Seat Heating, Front/Rear Window Heater, Climate Control)
 
The Regeneration may take up to 40 minutes, the engine speed automatically increases to about 1500 RPM.
[Select]
[01 - Engine]
[Coding-II - 11]
- Start Regeneration by Entering 10016.
 
[Do It!]
[Meas. Blocks - 08]
Select all 3 Groups at once 100, 101 and 102
[Go!]
MVB 100.1: Engine Speed
MVB 100.3: Regeneration Counter/Timer
MVB 100.4: Regeneration Abort recognized (0 = No Abort/1 = Abort recognized)
MVB 101.4: Regeneration Status (001 = Heating Up, 010 = Regeneration, 100 = Cooling Down)
MVB 102.1: Temperature before Catalyst
MVB 102.2: Temperature before Particle Filter
[Done, Go Back]
[Close Controller, Go Back - 06]