01423
From Ross-Tech Wiki
Revision as of 12:48, 10 November 2007 by RtWiKiSyS0p (talk | contribs)
01423 - Lateral Acceleration Sensor (G200)
01423 - Lateral Acceleration Sensor (G200): No or Incorrect Basic Setting / Adaptation
Possible Symptoms
- Malfunction Indicator Light (MIL) active
Possible Causes
- Basic Setting not performed
Possible Solutions
- Perform Basic Setting
01423 - Lateral Acceleration Sensor (G200): Electric Circuit Failure
Possible Symptoms
- Malfunction Indicator Light (MIL) active
Possible Causes
- Wiring/Connections from/to Lateral Acceleration Sensor (G200) faulty
- Supply Voltage insufficient
- Lateral Acceleration Sensor (G200) faulty
Possible Solutions
- Check Wiring/Connections from/to Lateral Acceleration Sensor (G200)
- Check Supply Voltage
- Check Lateral Acceleration Sensor (G200) faulty
- Perform Lateral Acceleration Sensor (G200) Basic Setting