VW Tiguan (5N) Brake Electronics
Coding
Coding for this Control Module is normally done via Software Version Management (SVM). If the old Control Module is still accessible read/copy it's Coding to the new Module. In case this is not possible please contact us directly and we will assist you with the Coding Process.
Every inquiry on this topic has to include a full Auto-Scan as well as which parts have been replaced and why, also make sure the Auto-Scan includes the complete VIN of the vehicle in question.
Basic Setting
Sensor for Steering Angle (G85)
Prerequisites:
- Start the vehicle.
- Drive in a short distance straight line on a level surface at a speed not higher than 20 km/h.
- While driving turn the steering wheel one turn to the right and one turn to the left.
- When having the steering wheel straight again stop the vehicle with the wheels pointed straight.
- Ensure that the steering wheel is not moved again.
- Keep the engine running and do not switch off the ignition.
- System voltage at least 12.0 V.
[Select]
[03 - Brake Electronics]
[Security Access - 16]
Enter 40168, to enable the basic setting.
[Do it!]
[Basic Settings - 04]
Group 060
[Go!]
Activate the Basic Setting.
[ON/OFF/Next]
After a successful basic setting, field 2 should say "OK".
[Done, Go Back]
To make sure the basic setting was succesful, check the sensor again.
[Measuring Blocks - 08]
Group 004
[Go!]
Check field 1, the value has to be between -1.5 and +1.5 °.
[Done, Go Back]
[Close Controller, Go Back - 06]
Note: After successful basic setting, the Steering Limit Stop needs to be adapted too.
Lateral/Longitudinal Acceleration & Yaw Rate Sensor (G200/G202/G251)
Prerequisites:
- System voltage at least 12.0 V.
[Select]
[03 - Brake Electronics]
[Measuring Blocks - 08]
Group 004
[Go!]
Check field 2, 3 and 4 - their value has to be between -1.5 and +1.5 m/s² or °/s.
[Done, Go Back]
[Security Access - 16]
Enter 40168, to enable the basic setting.
[Do it!]
[Basic Settings - 04]
Group 061
[Go!]
Activate the Basic Setting.
[ON/OFF/Next]
After a successful basic setting, field 2 should say "OK".
[Done, Go Back]
To make sure the basic setting was succesful, check the sensor again.
[Measuring Blocks - 08]
Group 004
[Go!]
Check field 2, 3 and 4 - their value has to be between -1.5 and +1.5 m/s² or °/s.
[Done, Go Back]
[Close Controller, Go Back - 06]
Brake Pressure Sensor 1 (G201)
Prerequisites:
- System voltage at least 12.0 V.
[Select]
[03 - Brake Electronics]
[Measuring Blocks - 08]
Group 005
[Go!]
Check field 1, the value has to be between -8.0 and +8.0 bar.
[Done, Go Back]
[Security Access - 16]
Enter 40168, to enable the basic setting.
[Do it!]
[Basic Settings - 04]
Group 066
[Go!]
Activate the Basic Setting.
[ON/OFF/Next]
After a successful basic setting, field 3 should say "OK".
[Done, Go Back]
To make sure the basic setting was succesful, check the sensor again.
[Measuring Blocks - 08]
Group 005
[Go!]
Check field 1, the value has to be between -3.8 and +3.8 bar.
[Done, Go Back]
[Close Controller, Go Back - 06]