18439/P2007/008199
From Ross-Tech Wiki
18439/P2007/008199 - Intake Manifold Runner Control Stuck Closed, Bank 2
Possible Symptoms
- MIL On
- Reduction of power at higher RPMs
Possible Causes
- Vacuum leak
- Faulty Intake Manifold Runner Position Sensor2 (G512)
- Intake Manifold Runner binding or sticking
Possible Solutions
- Replace failed vacuum line
- Check Intake Manifold Runner Position Sensor 2 (G512) and wiring, see repair manual.
Special Notes
- When found in 2005 - 2008 Audi A4 and A6 with 3.2L FSI engines, please see TSB 2019485/1.