00898 - Control Circuit A/C Compressor
00898 - Control Circuit A/C Compressor: Open or Short to Plus
Possible Symptoms
- Climate Control not working
Possible Causes
- Fuse(s) faulty
- Wiring and/or Connector(s) from/to Compressor Regulating Valve (N280) faulty
- Compressor Regulating Valve (N280) faulty
- Heating/Climate Control Module (J301) faulty
Possible Solutions
- Check Fuse(s)
- Check Wiring and/or Connector(s) from/to Compressor Regulating Valve (N280)
- Check/Replace Compressor Regulating Valve (N280)
- Check Measuring Value Blocks (MVB)
- Perform Output Test
- Check/Replace Heating/Climate Control Module (J301)
Special Notes
- The Compressor Regulating Valve (N280) may not be available separately, in this case the entire Refrigerant Compressor needs to be replaced.
00898 - Control Circuit A/C Compressor: Short to Ground
Possible Symptoms
- Climate Control not working
Possible Causes
- Fuse(s) faulty
- Wiring and/or Connector(s) from/to Compressor Regulating Valve (N280) faulty
- Compressor Regulating Valve (N280) faulty
- Heating/Climate Control Module (J301) faulty
Possible Solutions
- Check Fuse(s)
- Check Wiring and/or Connector(s) from/to Compressor Regulating Valve (N280)
- Check/Replace Compressor Regulating Valve (N280)
- Check Measuring Value Blocks (MVB)
- Perform Output Test
- Check/Replace Heating/Climate Control Module (J301)
Special Notes
- The Compressor Regulating Valve (N280) may not be available separately, in this case the entire Refrigerant Compressor needs to be replaced.