P261A/009754
From Ross-Tech Wiki
Revision as of 12:50, 6 March 2023 by Peter (talk | contribs) (→P261A/009754 VCDS-EN-210405 Coolant Pump 2: Open circuit)
P261A/009754 Coolant Pump 2: Open circuit
Possible Symptoms
- Fault code stored in memory, no check engine light
- Coolant pump is not operating
- "In certain North American vehicles with a 2.0L TFSI gasoline engine, the electric (after run) coolant pump may short circuit and/or overheat, potentially leading to a vehicle fire"
Possible Causes
- Faulty electrical coolant pump
- Coolant pump is disconnected
- If Recall/Service Action 19N4 was completed, the coolant pump will be disconnected and no fault code will be present.
- If the above is true, then the vehicle should have an open Campaign for the 19N8 Service action
- If Recall/Service Action 19N4 was completed, the coolant pump will be disconnected and no fault code will be present.
Possible Solutions
- Install a new electric (after-run) coolant pump and update ECM software (Audi dealer only)
- Check VIN here to see if there is an open campaign: https://web.audiusa.com/recall/# Audi Recall Service Campaign Lookup
Special Notes
- When found in certain 2012 ~ 2017 Audi vehicles with a 2.0L TFSI gasoline engine
- Please see this Safety Recall, Code: 19N8 - April 16, 2019
- https://static.nhtsa.gov/odi/tsbs/2019/MC-10159409-0001.pdf NHTSA Service action 19N8
- Please see this Safety Recall, Code: 19N8 - April 16, 2019
- Note: 19N4 is no longer and was replaced with 19N8
- For reference: 19N4 - September 14, 2018
- https://static.nhtsa.gov/odi/rcl/2018/RCRIT-18V229-7490.pdf NHTSA Service action 19N4
- For reference: 19N4 - September 14, 2018