As per Peter's suggestion, bundling Level Control information into wiki pages... looking to break this down into non UDS and UDS.

Page titles:
Level Control, UDS
Level Control, non-UDS


Looking at component info to help people ID or verify what version they have.


non-UDS (legacy):
Component: LUFTFDR.-CDC
Component: J197 LUFTFEDER
Component: - 2C1A1


UDS:
Component: LUFE-DAEMPFER


page title: Level Control, UDS


This information applies to Level Control, UDS versions. This can be identified by evaluating the data in the Auto-Scan:

Address 34: Level Control (J197)       Labels:. 4G0-907-553.clb
   Part No SW: 4G0 907 553 G    HW: 4G0 907 553 F
   Component: LUFE-DAEMPFER H19 0783
  • If LUFE-DAEMPFER is not shown in the Component field, this information may not apply.


Re-adapt Adaptive Suspension to default position

Special Notes, warnings, etc

  • Do not at any point in time select Basic Settings [IDE01475] Resetting of all adaptations.
  • Make sure you perform and save an [Auto-Scan] before beginning any work.
  • If there is an 'incorrectly coded' fault in the [34-Level Control], the controller will need to be coded first.
  • If you are attempting to alter the ride height use this procedure at your own risk!


Prerequisites

  • Ignition ON, use a Battery maintainer
  • Vehicle on level surface
  • No persons or gear in Vehicle
  • Fuel Tank 60% or more
  • Nothing under vehicle
  • Doors are to remain shut during the entire procedure
  • No faults in the [34-Level Control] controller other than "No or incorrect Basic Settings"


[34-Level Control]
[Security Access-16]

  • Enter 201013

[Basic Settings - 04]

  • [IDE03804] Deactivating loading mode

[Go!] After the result of Finished Correctly appears click [Stop]

  • [IDE03751] Activate level control

[Go!] After the result of Finished Correctly appears click [Stop]

  • [IDE03761] Delete calibration for level control

[Go!] After the result of Finished Correctly appears click [Stop]

  • [IDE03802] Set reference level

[Go!] After the result of Finished Correctly appears click [Stop]