19561/P3105/012549
From Ross-Tech Wiki
Revision as of 04:43, 10 August 2006 by RtWiKiSyS0p (talk | contribs)
19561/P3105/012549 - Valve for Intake Manifold Flap (N239): Open or Short to Ground
Possible Symptoms
- Engines shakes at shutdown
Possible Causes
- Wiring Open Circuit or Short to Ground
- Valve for Intake Manifold Flap (N239) faulty
Possible Solutions
- Check Wiring for Open Circuit or Short to Ground
- Check Valve for Intake Manifold Flap (N239)