00575

From Ross-Tech Wiki
Revision as of 12:27, 3 March 2007 by RtWiKiSyS0p (talk | contribs)

00575 - Intake Manifold Pressure: Control Limit Not Reached

Possible Symptoms

  • Sudden complete loss of Power
  • Reduced Power

Possible Causes

  • Hoses incorrect connected, disconnected, blocked or leaking
  • Pressure Unit for Turbo Charger defective
  • Solenoid Valve for Boost Pressure Control (N75) defective

Possible Solutions

  • Check Hoses
  • Check Pressure Unit for Turbo Charger
  • Check Solenoid Valve for Boost Pressure Control (N75)
  • Check Basic Setting > MVB 011


00575 - Intake Manifold Pressure: Control Limit Exceeded

Possible Symptoms

  • Sudden complete loss of Power
  • Reduced Power
  • Charge Pressure too High

Possible Causes

  • Solenoid Valve for Boost Pressure Control (N75) defective
  • Turbo Charger defective

Possible Solutions

  • Check Solenoid Valve for Boost Pressure Control (N75)
  • Check Basic Setting > MVB 011


00575 - Intake Manifold Pressure: Control Difference

Possible Symptoms

  • Reduced Power

Possible Causes

  • Solenoid Valve for Boost Pressure Control (N75) defective
  • Hoses incorrect connected, disconnected, blocked or leaking

Possible Solutions

  • Check Solenoid Valve for Boost Pressure Control (N75)
  • Check Hoses