00779
From Ross-Tech Wiki
Revision as of 11:52, 3 June 2007 by RtWiKiSyS0p (talk | contribs)
00779 - Outside Air Temperature Sensor (G17)
00779 - Outside Air Temperature Sensor (G17): Open or Short to Plus
Possible Symptoms
- In the Instrument Cluster you see dashes (---) instead of a temperature
Possible Causes
- Wiring between Outside Air Temperature Sensor (G17) and Instrument Cluster: Open or Short Circuit
Possible Solutions
- Check wiring between Outside Air Temperature Sensor (G17) and Instrument Cluster
- Check Measuring Block Value
00779 - Outside Air Temperature Sensor (G17): Short to Ground
Possible Symptoms
- In the Instrument Cluster you see dashes (---) instead of a temperature
Possible Causes
- Outside Air Temperature Sensor (G17) damaged
Possible Solutions
- Check / Replace Outside Air Temperature Sensor (G17)