16492/P0108 - Manifold Absolute Pressure (MAP) (G71) or Barometric Pressure (BARO) (F96): Signal High
Possible Symptoms
- unknown
Possible Causes
- Wiring and/or connections faulty (Short to Plus)
- Leak in intake and/or exhaust
- G71 and/or F96 faulty
- Control Module faulty
Possible Solutions
- Check wiring and connections
- Check for leak in intake or exhaust
- Check / Replace G71 and/or F96
- Check / Replace Controle Module