01423

From Ross-Tech Wiki
Revision as of 09:10, 6 March 2008 by RtWiKiSyS0p (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

01423 - Lateral Acceleration Sensor (G200)

01423 - Lateral Acceleration Sensor (G200): No or Incorrect Basic Setting / Adaptation

Possible Symptoms

  • Malfunction Indicator Light (MIL) active

Possible Causes

  • Lateral Acceleration Sensor (G200) Basic Setting lost/not performed

Possible Solutions

  • Perform Lateral Acceleration Sensor (G200) Basic Setting


01423 - Lateral Acceleration Sensor (G200): Electric Circuit Failure

Possible Symptoms

  • Malfunction Indicator Light (MIL) active

Possible Causes

  • Wiring/Connections from/to Lateral Acceleration Sensor (G200) faulty
  • Supply Voltage insufficient
  • Lateral Acceleration Sensor (G200) faulty

Possible Solutions

  • Check Wiring/Connections from/to Lateral Acceleration Sensor (G200)
  • Check Supply Voltage
  • Check Lateral Acceleration Sensor (G200) faulty
  • Perform Lateral Acceleration Sensor (G200) Basic Setting