28827/U0155/049493

From Ross-Tech Wiki
Revision as of 17:08, 26 May 2008 by RtWiKiSyS0p (talk | contribs) (New page: __FORCETOC__ == U0155/049493 - No Communication with Instrument Cluster == ==== Possible Symptoms ==== * Malfunction Indicator Lamp (MIL) active ==== Possible Causes ==== * Connector(...)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

U0155/049493 - No Communication with Instrument Cluster

Possible Symptoms

  • Malfunction Indicator Lamp (MIL) active

Possible Causes

  • Connector(s)/Wiring from/to Instrument Cluster faulty
  • Databus Communication faulty

Possible Solutions

  • Check Connector(s)/Wiring from/to Instrument Cluster
  • Check Databus Communication
    • See Measuring Value Blocks (MVB)

Special Notes

  • When found in Engine Control Module without any obvious cause (i.e. Measuring Value Blocks show plausible Values)
    • Check Oil Level and Temperature Sensor Installation Information in Instrument Cluster Adaptation Channel 039.