01331
From Ross-Tech Wiki
Revision as of 07:31, 14 June 2008 by RtWiKiSyS0p (talk | contribs) (New page: __FORCETOC__ == 01331 - Door Control Module; Driver Side (J386) == === 01331 - Door Control Module; Driver Side (J386): Supply Voltage Too Low === ==== Possible Causes ==== * Fuse(s) fa...)
01331 - Door Control Module; Driver Side (J386)
01331 - Door Control Module; Driver Side (J386): Supply Voltage Too Low
Possible Causes
- Fuse(s) faulty
- Wiring/Connectors from/to Control Module faulty
- Power Supply (Battery/Generator) faulty
Possible Solutions
- Check Fuse(s)
- Check/Repair Wiring/Connectors from/to Control Module
- Check Power Supply (Battery/Generator)
Special Notes
- When found in an individual control module, it's most likely a local source (e.g. wiring/connectors).
- When found in multiple control modules at the same time, it's most likely a common source (e.g. ground spot, battery, generator).
- Intermittent codes are often stored during low outside temperature when the battery capacity goes down and may be ignored.