17655/P1247/004679

From Ross-Tech Wiki
Revision as of 11:58, 25 February 2009 by RtWiKiSyS0p (talk | contribs) (New page: __FORCETOC__ == 17655/P1247/004679 - Needle Lift Sensor (G80): Open or Short to Plus == ==== Possible Symptoms ==== * Malfunction Indicator Light (MIL) ON * Pre-Glow Light ON * Rough Eng...)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

17655/P1247/004679 - Needle Lift Sensor (G80): Open or Short to Plus

Possible Symptoms

  • Malfunction Indicator Light (MIL) ON
  • Pre-Glow Light ON
  • Rough Engine Performance
  • Excessive Emissions

Possible Causes

  • Fuse(s) faulty
  • Wiring and/or Connector(s) from/to Needle Lift Sensor (G80) faulty
  • Needle Lift Sensor (G80) faulty

Possible Solutions

  • Check Fuse(s)
  • Check Wiring and/or Connector(s) from/to Needle Lift Sensor (G80)
  • Check/Replace Needle Lift Sensor (G80)