16795/P0411/001041

From Ross-Tech Wiki
Revision as of 04:03, 25 April 2009 by RtWiKiSyS0p (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

16795/P0411/001041 - Secondary Air Injection System: Incorrect Flow Detected

Possible Symptoms

  • Malfunction Indicator Light (MIL) ON

Possible Causes

  • Fuel Pump Relay (J17) faulty
  • Hoses/Pipes to/between Components faulty/clogged
  • Secondary Air Injection Pump (V101) faulty
  • Secondary Air Injection Pump Relay (J299) faulty
  • Secondary Air Injection Solenoid Valve (N112) faulty

Possible Solutions

  • Check Fuel Pump Relay (J17)
  • Check Hoses/Pipes to/between Components
    • Check Secondary Air Injection Hoses/Pipes for Carbonization
  • Check Secondary Air Injection Pump (V101)
  • Check Secondary Air Injection Pump Relay (J299)
  • Check Secondary Air Injection Solenoid Valve (N112)