01419 - Switch Valve 2 for Electronic Stability Program (N226)
Possible Symptoms
- Malfunction Indicator Light (MIL) ON
Possible Causes
- Fuse(s) faulty
- Wiring and/or Connector(s) from/to Brake Electronics (J104) faulty
- Wiring and/or Connector(s) from/to Valve Power Supply faulty
- Brake Electronics (J104) faulty
Possible Solutions
- Check Fuse(s)
- Check Wiring and/or Connector(s) from/to Brake Electronics (J104)
- Check Wiring and/or Connector(s) from/to Valve Power Supply
- Check/Replace Brake Electronics (J104)
- Perform Output Test