01420
From Ross-Tech Wiki
Revision as of 05:49, 22 March 2011 by RtWiKiSyS0p (talk | contribs) (Created page with '== 01420 - High Pressure Switch Valve 1 for Electronic Stability Program (N227) == ==== Possible Symptoms ==== * Malfunction Indicator Light (MIL) ON ==== Possible Causes ====…')
01420 - High Pressure Switch Valve 1 for Electronic Stability Program (N227)
Possible Symptoms
- Malfunction Indicator Light (MIL) ON
Possible Causes
- Fuse(s) faulty
- Wiring and/or Connector(s) from/to Brake Electronics (J104) faulty
- Wiring and/or Connector(s) from/to Valve Power Supply faulty
- Brake Electronics (J104) faulty
Possible Solutions
- Check Fuse(s)
- Check Wiring and/or Connector(s) from/to Brake Electronics (J104)
- Check Wiring and/or Connector(s) from/to Valve Power Supply
- Check/Replace Brake Electronics (J104)
- Perform Output Test