16606/P0222/000546 - Angle Sensor 2 for Throttle (G188): Signal Too Low

Possible Symptoms

  • Malfunction Indicator Light (MIL) ON

Possible Causes

  • Fuse(s) faulty
  • Wiring and/or Connector(s) from/to Throttle Angle Sensor 2(G188) faulty
  • Throttle Angle Sensor 2(G188) faulty

Possible Solutions

  • Check Fuse(s)
  • Check Wiring and/or Connector(s) from/to Throttle Angle Sensor 2(G188)
  • Check/Replace Throttle Angle Sensor 2(G188)
    • Check Measuring Value Blocks (MVB)