Audi A4 (8E) Automatic Roof
          From Ross-Tech Wiki
          
          
      
      
      
      Table Of Contents
Adaptation
Channel 01: Reset
Prerequisites:
- Automatic Roof closed
- Measuring Value Blocks (MVB) OK
To reset the switch positions, save a new value of 1.
Special Notes
- If Adaptation will not set with only the 02000 fault present, check TSB 61-08-05 (2010940, NAR only)
Reading Roof Electronics Switch Conditions, Electric Power Top Closed
| Measuring Block Group 001 | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Field 2 | X | Field 3 | Data | |||||||||||||
| 1 | 1 | 0 | 1 | 1 | 0 | 1 | 0 | 1 | 0 | X | 0 | 1 | 1 | 0 | F201 | |
| F290 | ||||||||||||||||
| F293 | ||||||||||||||||
| F200 | ||||||||||||||||
| X | ||||||||||||||||
| Not used, always "0" | ||||||||||||||||
| F292 | ||||||||||||||||
| X | ||||||||||||||||
| F171 | ||||||||||||||||
| F202 | ||||||||||||||||
| F294 | ||||||||||||||||
| F295 | ||||||||||||||||
| F172 | ||||||||||||||||
| Switch Point for Bow UP | ||||||||||||||||
| Switch Point for Bow OPEN | ||||||||||||||||
| Switch Point for Bow DEAD CENTER | ||||||||||||||||