User:Peter

From Ross-Tech Wiki
Revision as of 09:53, 3 May 2013 by Peter (talk | contribs)

Electronic Damping Control J250 - Basic Settings

[Select]
[14 - Susp. Elect]
[Meas. Blocks - 08]
Note the values stores in:
Group-054 Field-1 = G78( _Sensor)Min value
Group-054 Field-2 = G78( _Sensor)Max value
Group-055 Field-1 = G289( _Sensor)Min value
Group-055 Field-2 = G289( _Sensor)Max value

Look at: Group-003 Field-1,2,3 - If the values are with in the range of the Min - Max Basic settings can be performed, if not inspect suspension.

[Security Access - 16] Enter 31564, to enable the basic setting. [Do it!] [Basic Settings - 04] Group 001 [Go!] The New values should be displayed. - To check the learned values, check Measuring Value Group-008. [Meas. Blocks - 08] Enter [008] - Go! The values displayed should be the learned values as displayed in the Basic Settings window.