Electronic Damping Control J250 - Basic Settings

Prerequisites:
- Battery Voltage = 12.0 - 14.0
- No fault codes other than [01087-Basic Setting Not Performed]
- Vehicle is lifted off the ground, on a suitable vehicle lift


[Select]
[14 - Susp. Elect]
[Meas. Blocks - 08]
Note: The values stored in the Measuring Value Blocks below are the Minimum and Maximum sensor values.
Group-054 Field-1 = G78 - Min value
Group-054 Field-2 = G78 - Max value

Group-055 Field-1 = G289 - Min value
Group-055 Field-2 = G289 - Max value

Look at:
Group-003 - Field-1,2,3 - Actual Sensor values'
- If the values are with in the range of the Min - Max stored values from MVBs 054 and 055 then
Basic settings can be performed, if not inspect suspension or sensors.

[Security Access - 16]
Enter 31564, to enable the basic setting.
[Do it!]
[Basic Settings - 04]
Group 001
[Go!]

The New values should be displayed.
- To check the learned values, check Measuring Value Group-008.
[Meas. Blocks - 08]
Enter [008] - Go!
The values displayed should be the learned values as displayed in the Basic Settings window.