00266
From Ross-Tech Wiki
Table Of Contents
-
1.
00266 - Solenoid Valve 5 (N92)
-
1.1.1
00266 - Solenoid Valve 5 (N92): Open or Short to Ground
- 1.1.1.2 Possible Causes
- 1.1.2.2 Possible Solutions
- 1.1.3.2 Special Notes
-
1.1.1
00266 - Solenoid Valve 5 (N92): Open or Short to Ground
00266 - Solenoid Valve 5 (N92)
00266 - Solenoid Valve 5 (N92): Open or Short to Ground
Possible Causes
- Wiring/Connectors from/to Solenoid Valve 5 (N92) Open or Short to Ground
- Solenoid Valve 5 (N92) faulty
Possible Solutions
- Check/Repair Wiring/Connectors from/to Solenoid Valve 5 (N92)
- Check/Replace Solenoid Valve 5 (N92)
- See Measuring Value Blocks (MVB)
- Perform Output Test
Special Notes
- In some vehicles, (N92) may be refereed to as (N216) in the factory repair manual.