P06A3/001699

From Ross-Tech Wiki
Revision as of 09:21, 5 March 2024 by Peter (talk | contribs) (Created page with "== P06A3/001699 - Sensor Reference Voltage D: Too Low == ==== Possible Symptoms ==== * Malfunction Indicator Light (MIL) active * Poor engine performance ==== Possible Cau...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

P06A3/001699 - Sensor Reference Voltage D: Too Low

Possible Symptoms

  • Malfunction Indicator Light (MIL) active
  • Poor engine performance

Possible Causes

  • Low ECM voltage to ECM
  • Faulty wiring on Sensor Reference Voltage "D" Circuit
  • Faulty sensor or component on Sensor Reference Voltage "D" Circuit
  • Faulty ECM

Possible Solutions

  • Verify ALL Powers and Grounds for the ECM
  • Check wiring on Sensor Reference Voltage "D" Circuit
  • Check sensors and components on the Sensor Reference Voltage "D" Circuit
  • Check wiring at the ECM with all components removed from the Circuit to verify the reference voltage is present.