P06A3/001699
From Ross-Tech Wiki
P06A3/001699 - Sensor Reference Voltage D: Too Low
Possible Symptoms
- Malfunction Indicator Light (MIL) active
- Poor engine performance
Possible Causes
- Low ECM voltage to ECM
- Faulty wiring on Sensor Reference Voltage "D" Circuit
- Faulty sensor or component on Sensor Reference Voltage "D" Circuit
- Faulty ECM
Possible Solutions
- Verify ALL Powers and Grounds for the ECM
- Check wiring on Sensor Reference Voltage "D" Circuit
- Check sensors and components on the Sensor Reference Voltage "D" Circuit
- Check wiring at the ECM with all components removed from the Circuit to verify the reference voltage is present.