Difference between revisions of "00264"

From Ross-Tech Wiki
 
 
Line 1: Line 1:
 
__FORCETOC__
 
__FORCETOC__
== 00264 - Solenoid valve 4 (N91): open circuit / short to ground ==
+
== 00264 - Solenoid Valve 4 (N91) ==
 +
=== 00264 - Solenoid Valve 4 (N91): Open or Short to Ground ===
  
 
==== Possible Causes ====
 
==== Possible Causes ====
  
* Open circuit or short circuit in wiring
+
* Wiring/Connectors from/to Solenoid Valve 4 (N91) Open or Short to Ground
* (K2 clutch) Malfunctioning solenoid valve 4
+
* Solenoid Valve 4 (N91) faulty
  
 
==== Possible Solutions ====
 
==== Possible Solutions ====
  
* Check wiring, connections and solenoid
+
* Check/Repair Wiring/Connectors from/to Solenoid Valve 4 (N91)
* Replace N91
+
* Check/Replace Solenoid Valve 4 (N91)
 +
** See Measuring Value Blocks (MVB)
 +
** Perform Output Test
  
 
[[Category:Fault Codes]]
 
[[Category:Fault Codes]]

Latest revision as of 05:32, 22 March 2007

00264 - Solenoid Valve 4 (N91)

00264 - Solenoid Valve 4 (N91): Open or Short to Ground

Possible Causes

  • Wiring/Connectors from/to Solenoid Valve 4 (N91) Open or Short to Ground
  • Solenoid Valve 4 (N91) faulty

Possible Solutions

  • Check/Repair Wiring/Connectors from/to Solenoid Valve 4 (N91)
  • Check/Replace Solenoid Valve 4 (N91)
    • See Measuring Value Blocks (MVB)
    • Perform Output Test