00268

From Ross-Tech Wiki
Revision as of 11:10, 22 May 2013 by Jef (talk | contribs) (→‎Possible Solutions)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

00268 - Solenoid Valve 6 (N93)

00268 - Solenoid Valve 6 (N93): Open or Short to Ground

Possible Causes

  • Wiring/Connectors from/to Solenoid Valve 6 (N93) Open or Short to Ground
  • Solenoid Valve 6 (N93) faulty

Possible Solutions

  • Check/Repair Wiring/Connectors from/to Solenoid Valve 6 (N93)
  • Check/Replace Solenoid Valve 6 (N93)
    • See Measuring Value Blocks (MVB)
    • Perform Output Test

Special Notes

  • On some transmissions, the OE wiring diagrams do not have Solenoid Valve 6 (N93), it can be refereed to as the Pressure Control Valve 3 (N217).