00603

From Ross-Tech Wiki
Revision as of 21:53, 9 June 2010 by Dana (talk | contribs) (Created page with '__FORCETOC__ == 00603 - Footwell / Defroster Flap Motor (V85) == === 00603 - Footwell / Defroster Flap Motor (V85): Faulty === ==== Possible Causes ==== * Wiring/Connectors fr…')
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

00603 - Footwell / Defroster Flap Motor (V85)

00603 - Footwell / Defroster Flap Motor (V85): Faulty

Possible Causes

  • Wiring/Connectors from/to Footwell / Defroster Flap Motor (V85)
  • Positioning Motor for Footwell / Defroster Flap Motor (V85) blocked
  • Positioning Motor for Footwell / Defroster Flap Motor (V85) faulty

Possible Solutions

  • Check Footwell / Defroster Flap Motor (V85)
    • See Measuring Value Blocks (MVB)
    • Perform Output Test
    • Perform Basic Setting
  • Check/Repair Wiring and Connectors
  • Check/Repair Obstructions or Blockage

Special Notes

  • Common HVAC Basic Settings Group(s) include 000 -or- 001