==== Special Notes ====
 
==== Special Notes ====
  
* Pickup Coils for Immobilizer 2 and 3 Systems should read ~23.5 Ohms.
+
* Pickup Coils for Immobilizer 2 and 3 Systems should read ~ 18 to 24 Ω
  
 
__FORCETOC__
 
__FORCETOC__
 
[[Category:Fault Codes]]
 
[[Category:Fault Codes]]

Latest revision as of 11:37, 31 October 2016

01128 - Immobilizer Pickup Coil (D2)

Possible Symptoms

  • Immobilizer Warning Light flashing
  • Immobilizer active (Engine shuts OFF after 2-3 Seconds)

Possible Causes

  • Wiring and/or Connector(s) from/to Immobilizer Pickup Coil (D2) faulty
  • Immobilizer Pickup Coil (D2) faulty
  • Immobilzier Control Module faulty

Possible Solutions

  • Check Wiring and/or Connector(s) from/to Immobilizer Pickup Coil (D2)
  • Check/Replace Immobilizer Pickup Coil (D2)
    • Check Measuring Value Blocks (MVB)

Special Notes

  • Pickup Coils for Immobilizer 2 and 3 Systems should read ~ 18 to 24 Ω